Repository navigation
Add G1 ankle coupled limits via fixed tendons - #1367
Merged
Merged
Conversation
qiayuanl
force-pushed
the
qiayuanl/g1-ankle-coupled-limits
branch
from
November 16, 2026 23:30
a17d020 to
78fe4e9
Compare
qiayuanl
marked this pull request as ready for review
November 16, 2026 23:33
qiayuanl
force-pushed
the
qiayuanl/g1-ankle-coupled-limits
branch
from
November 17, 2026 00:19
78fe4e9 to
d8bf5f6
Compare
Two push rods drive the G1 ankle, so its mechanical stops couple roll and pitch. Four fixed tendons per ankle bound the (roll, pitch) region with the linear limits measured on hardware, as described in https://kzakka.com/closing-the-loop/. Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
qiayuanl
force-pushed
the
qiayuanl/g1-ankle-coupled-limits
branch
from
November 17, 2026 23:36
d8bf5f6 to
c11ebdb
Compare
kevinzakka
approved these changes
Nov 17, 2026
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Two push rods drive the G1 ankle, so its mechanical stops couple roll and pitch. The model so far limits the two joints independently, which allows poses the hardware cannot reach.
This adds 4 fixed tendons per ankle that bound the (roll, pitch) region with the linear limits measured on hardware, as described in Closing the loop. The tendon limits use the default solver parameters, as the joint limits do.
🤖 Generated with Claude Code