Skip to content

Problem with CRTM installation on Orion #527

Description

@CatherineThomas-NOAA

Describe the bug
CI testing for the global-workflow on Orion results in this error message in the log file (as seen in g-w PR 1818):

73: Apply_AntCorr(FAILURE) : Input iFOV inconsistent with AC data

These errors are from a problem with the CRTM installation. As pointed out by @emilyhcliu, the MHS Metop-C coefficient file is incorrect; it is too small. It only contains header information:

Orion-login-4[4] cthomas$ pwd
/apps/contrib/NCEP/libs/hpc-stack/intel-2018.4/crtm/2.4.0/fix
Orion-login-4[5] cthomas$ ls -l mhs*metop-?.*
-rw-r----- 1 8536 noaa-hpc 11396 Feb  4  2022 mhs_metop-a.SpcCoeff.bin
-rw-r----- 1 8536 noaa-hpc 49212 Feb  4  2022 mhs_metop-a.TauCoeff.bin
-rw-r----- 1 8536 noaa-hpc 11396 Feb  4  2022 mhs_metop-b.SpcCoeff.bin
-rw-r----- 1 8536 noaa-hpc 49212 Feb  4  2022 mhs_metop-b.TauCoeff.bin
-rw-r----- 1 8536 noaa-hpc   492 Feb  4  2022 mhs_metop-c.SpcCoeff.bin
-rw-r----- 1 8536 noaa-hpc 49212 Feb  4  2022 mhs_metop-c.TauCoeff.bin

Expected behavior
The MHS Metop-C files should be the same size as Metop-A and Metop-B.