Machine counter browser checks

Ready-to-use local demo

Log in as an admin or supervisor and open:

http://localhost:8080/admin/connectivity/counters?counter=2

This session left that fresh demo at zero. Counter 1 contains the completed automated walkthrough and its audit history. These IDs belong to this development database only. The demo has its own line, product, order and two batches of 10 pieces each, sharing one station. It does not connect to a PLC or broker. The page is also linked from Connectivity → Overview → Machine counters (Polish: Połączenia → Przegląd → Liczniki maszyn).

For another fresh demo, run from the repository root on the local development installation:

docker exec openmmes-backend php artisan machine-counters:demo 1 --force

1 is this installation's admin user ID. The command prints a new URL and never resets existing data. --force is needed because this local Docker instance uses APP_ENV=production; do not use this command against your production database. Simulation controls are restricted to these CLI-created test sources. Normal machine channels cannot enable simulation through the web UI.

Walkthrough

Use Raw count / Wartość surowa → Send test reading / Wyślij odczyt testowy. Leave the event ID and timestamp empty until instructed otherwise. The simulator stamps the current acquisition time; real gateways must supply their acquisition timestamp.

Step Browser action Expected result
1 Send 1000, then 1003. First reading establishes the baseline: 0 good. Second reading: batch 1 has 3 good.
2 Send 1003 again. Still 3 good; history says Unchanged / Bez zmian.
3 Send 2, then 1010. Both leave output at 3. Reset review required remains active even after the raw count exceeds the old value.
4 Enter a reset reason and click Establish new baseline / Ustal nową wartość bazową. Send 10, then 12. 10 becomes the new baseline with no output. 12 adds 2: batch 1 now has 5 good.
5 Select Demo batch 2 under Assigned batch step, enter a reason, save configuration. Send 20, then 22. Batch 2 starts at 0, then reaches 2. Batch 1 stays at 5.
6 Select Unassigned / Nieprzypisane, enter a reason, save. Send 30, then 33. 30 is a baseline; the delta of 3 is retained as unassigned, with 0 applied. Neither batch changes.
7 On that unassigned row, click Review / Przejrzyj. Choose Apply remaining good quantity, select batch 2, enter a reason, save. A separate Reconciled / Uzgodniono audit row applies 3 to batch 2. The original row retains its original attribution and cannot be reviewed twice.
8 Assign the channel back to batch 2 and save with a reason. Batch 2 shows 5 good. Assigning a channel does not replay old readings.
9 Change mode to Pulse / Impuls, keep quality Good, save with a reason. Send 1 with an empty event ID. Nothing counted; history says Event ID required.
10 Send 1 with ID manual-pulse-1; repeat it; send 1 with ID manual-pulse-2. Batch 2 progresses 6 → 6 → 7. Reusing an event ID returns the existing reading; it creates no second production entry.
11 Send 1 with a new ID and timestamp 2020-01-01T12:00:00Z; then another new ID with 2099-01-01T12:00:00Z. Clear the timestamp afterward. Both are retained as out-of-order/future readings. Output stays at 7.
12 Change mode to Increment / Przyrost, save, send 5 with ID manual-overflow. Batch 2 reaches its 10-piece limit. History records delta 5, applied 3, status Partially applied. The remaining 2 require explicit review.
13 Change to Cumulative and quality Total (quality unknown), save, send 100, then 103. No additional good output; the three unclassified pieces are retained for quality review. Repeat with quality Reject, values 0 → 2: still no good output.
14 Click Awaiting review / Do weryfikacji. Review a quality row and choose Dismiss with reason. The row leaves the pending queue, and its reason remains in All readings. Total/reject readings cannot be silently converted into good output.

The current step's good count appears above its configuration. To inspect the other batch, select that batch in configuration and save with a reason. This establishes a new counting boundary, so subsequent cumulative readings need a fresh baseline.

Try an unrelated workstation in configuration: saving must show a form error and preserve the existing assignment. At a mobile viewport, the forms must fit; the history table scrolls horizontally inside its own container.

Production-flow checks from the earlier changes

On an isolated routed order with Transfer enabled under Settings → System:

  1. Start the first step of a 10-piece batch; log 4 good + 1 scrap.
  2. The next station becomes ready with 4 incoming while the first step is still running.
  3. At the next step, attempting to log more than those 4 must fail. Log 2 good and check that only 2 arrive downstream. Final order output comes only from the final effective step.
  4. Attempt to finish the first step with 5 pieces still waiting: it must fail. Record the remaining quantity before finishing. Downstream completion also waits for upstream closure.
  5. Pause the order or open a blocking issue/QC task: output logging must stop.
  6. Classify a generated scrap entry: the reason can change, but its quantity, step/order association and deletion must remain protected.
  7. Open two operator sessions on the same line. A valid quantity change must refresh the other view; a session on another line must not receive that private line update.

Do not change the global production-flow setting while real work is running.

Recording and verification

The visible native playwright-iso walkthrough was recorded with Playwright's recordVideo context option, saved as docs/review-evidence/counter-e2e-2026-09-15/counter-walkthrough.webm. Screenshots in the same directory cover the baseline/reset, assignment/reconciliation, quantity caps, quality handling and a 390-pixel mobile viewport. These local evidence files are intentionally excluded from the application commit.

See deployment requirements before enabling machine writes.

Check upgrade compatibility

Use a separate CLI-created demo for this check. Flow is a global setting: do this only on the isolated development instance, and restore its original value afterward.

  1. In Settings → System → Production, select Whole batch and save.
  2. Open the demo counter, expand Return to legacy counting, enter a reason and submit.
  3. Reload the page. It must still say Legacy counting is active and offer Enable explicit counting. Opening the page has not migrated the source.
  4. Try enabling Transfer in system settings. Saving must fail with the incompatible tag ID.
  5. Return to the counter, choose its workstation and Demo batch 1, enter a reason and click Enable explicit counting. Send 1000 → 1003 → 1003: good output must be 0 → 3 → 3.
  6. Enable Transfer again. With compatible channels and matching order/step totals, saving succeeds.
  7. Attempt Return to legacy counting while Transfer is active: the form must reject it.

Legacy MQTT payloads and Modbus/OPC UA readings without new event metadata are covered by backend integration tests. For real installations, keep existing publishers unchanged until their own channel is migrated. If a whole-batch machine order already has output that is not represented in its steps, finish or reconcile it before enabling Transfer; the settings gate reports it.

Compatibility recording: docs/review-evidence/counting-compatibility/compatibility.webm.

Manual correction regression (Polish UI)

Use a separate test order with counting source Operator, transfer flow, quantity 10, and at least two sequential steps. Enable Korekty ilości produkcji → Pełna edycja for this test and use the operator who started the step. Restore the previous policy afterward. Do not reuse live production work.

  1. Start the first step and log 4 good pieces. The next step receives 4.
  2. Expand Skoryguj ilość dobrych sztuk. Enter total 3 and a reason, then Zapisz korektę. The first step shows 3 passed and 7 waiting; the next receives 3. The audit retains 4 → 3.
  3. Start the next step and log 2 good pieces. Try correcting the first total to 1. An inline error must appear and both counts must remain unchanged.
  4. Correct the next total to 1 with a reason, then the first total to 1. Both are allowed.
  5. On the final step, a valid correction must also update the order's produced quantity.
  6. Check an old form after another session changes its total: submission must require refresh.
  7. Blank reasons, more than two decimals, machine-counted and completed steps are refused.
  8. In System settings, try switching to Cała partia with this order open: the switch must fail and retain Przekazywanie. Finish/cancel test work when testing is complete.